登录 | 注册    关注公众号  
微信公众号
搜索
 >  Kits>SCF >CEA-C078

ClinMax™ Human SCF ELISA Kit

For research use only.

产品描述(Product Details)

Assay TypeSandwich-ELISA
AnalyteSCF
Format96T
ReactivityHuman
Sensitivity15.625 pg/mL
Standard Curve Range31.25 pg/mL-2000 pg/Ml
Assay Time3 hr 15 min
Suitable Sample TypeFor the quantitative determination of human SCF in Cell Culture Supernatants, Plasma, Serum.
Sample volume50 μL

组分(Materials Provided)

IDComponentsSize
CEA078-C01Pre-coated Anti- SCF Antibody Microplate1 plate
CEA078-C02Human SCF Standard20μg ×2
CEA078-C03Biotin-Anti-SCF Antibody Con. Solution200 μL
CEA078-C04Biotin-Antibody Dilution Buffer8 mL
CEA078-C05Streptavidin-HRP Con. Solution500 uL
CEA078-C06Streptavidin-HRP Dilution Buffer15 mL
CEA078-C0720× Washing Buffer50 mL
CEA078-C08Sample Dilution Buffer15 mL ×2
CEA078-C09Substrate Solution12 mL
CEA078-C10Stop Solution6 mL

背景(Background)

ClinMax™ ELISA Kit is convenient ready-to-use immunoassay Kit, specifically designed to quantitate human SCF that is present in complex biological samples, such as human serum, plasma, and cell culture supernates.

A comprehensive validation of the ELISA method was performed following the ICH M10 on bioanalytical method validation and the FDA’s bioanalytical method validation guidance for industry. This validation included assessments of linearity, accuracy, precision, dilution linearity, recovery, and the hook effect. For details information, please refer to the DS.

ClinMax™ ELISA Kits are manufactured in a GMP-certified facility and comply to the ISO 13485 standard, ensuring a high level of quality and reliability.

应用说明(Application)

The kit is developed for quantitative detection of human SCF in serum, plasma and cell culture supernates.

It is for research use only.

存储(Storage)

Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

原理(Assay Principles)

SCF Assay Principles

 

典型数据-Typical Data Please refer to DS document for the assay protocol.

SCF TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of SCF is less than 15.625 pg/mL.

 

验证(Validation)

批内差异(Intra-Assay Statistics)

Ten replicates of each of 4 samples containing different SCF concentrations were tested in one assay. Acceptable criteria: CV<10%.

SCF INTRA-ASSAY STATISTICS

批间差异(Inter-Assay Statistics)

Five samples containing different concentrations of SCF were tested in independent assays. Acceptable criteria: CV<15%.

SCF INTER-ASSAY STATISTICS

回收率(Recovery)

Recombinant SCF was spiked into 3 human serum samples, and then analyzed. The average recovery of SCF for serum samples is 103.2%.

SCF RECOVERY

 

背景(Background):SCF

Stem cell factor (also known as SCF, KIT-ligand, KL, or steel factor) is a cytokine that binds to the c-KIT receptor (CD117). SCF can exist both as a transmembrane protein and a soluble protein. This cytokine plays an important role in hematopoiesis (formation of blood cells), spermatogenesis, and melanogenesis.

 