试剂盒标准品经WHO标准品进行校准;
采用一步法,2h内即可完成80+样本检测;
经细胞培养基及血清真实样本等检测,基质干扰小;
遵循ISO9001和ISO13485双重质量体系,批间差异有保障;
基于ACRO自主蛋白原料平台开发,产品性能、供货能力及长期稳定性保障;
可提供方法学验证报告,严格控制产品灵敏度、特异性、准确度、线性和批间/批内差。
RUO | PRO | |||
---|---|---|---|---|
Molecule | Cat. No. | Product Description | Cat. No. | Product Description |
IFN-γ | CRS-A017 | ClinMax™ Human Interferon-γ(IFN-γ) ELISA Kit | CEA-C006 | ClinMax™ Human IFN-γ ELISA Kit, PRO |
TNF-α | CRS-A002 | ClinMax™ Human Tumor Necrosis Factor Alpha (TNF-α) ELISA Kit | CEA-C010 | ClinMax™ Human TNF-α ELISA Kit, PRO |
IL-6 | CRS-B001 | ClinMax™ Human IL-6 ELISA Kit | CEA-C001 | ClinMax™ Human IL-6 ELISA Kit, PRO |
IL-1 beta | CRS-B002 | ClinMax™ Human IL-1beta ELISA Kit | CEA-C002 | ClinMax™ Human IL-1β ELISA Kit, PRO |
IL-4 | CRS-B003 | ClinMax™ Human IL-4 ELISA Kit | CEA-C003 | ClinMax™ Human IL-4 ELISA Kit, PRO |
IL-8 | CRS-B004 | ClinMax™ Human IL-8 ELISA Kit | CEA-C004 | ClinMax™ Human IL-8 ELISA Kit, PRO |
IL-10 | CRS-B005 | ClinMax™ Human IL-10 ELISA Kit | CEA-C005 | ClinMax™ Human IL-10 ELISA Kit, PRO |
GM-CSF | CRS-B007 | ClinMax™ Human GM-CSF ELISA Kit | CEA-C007 | ClinMax™ Human GM-CSF ELISA Kit, PRO |
IL-2 | CRS-B008 | ClinMax™ Human Interleukin-2(IL-2) ELISA Kit | CEA-C008 | ClinMax™ Human IL-2 ELISA Kit, PRO |
IL-12 (P70) | CRS-B009 | ClinMax™ Human IL-12p70 ELISA Kit | CEA-C009 | ClinMax™ Human IL-12p70 ELISA Kit, PRO |
RUO | PRO | ||
---|---|---|---|
实验时长 | 2-3h | 2h | |
样本类型 | Cell Culture Supernates, Serum , Plasma | Cell Culture Supernates, Serum , Plasma | |
质量管理体系 | ISO13485 | ||
验证参考 | ICH M10 | ||
验证实验 | Hook效应 | √ | √ |
长期稳定性验证 | √ | √ | |
样本源干扰 | 胆红素、甘油三酯、血红蛋白 | ||
抗凝剂干扰 | 肝素钠、柠檬酸、EDTA | ||
样本保存干扰 | 冻融、4℃保存 | ||
特异性 | IL-2, IL-4, IL-6, IL-7, IL-10, IL-15, IL-21, IL-1β, TNF-alpha, GM-CSF | IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 p70, IL-13, IL-15, IL-17, GM-CSF, TNF-alpha, IFN-gamma, etc. |
The sensitivity of ClinMax™ Human Interferon-γ (IFN-γ) ELISA Kit (Cat. No. CRS-A017) is 5.309 pg/Ml.
ClinMax™ Human Interferon-γ (IFN-γ) ELISA Kit (Cat. No. CRS-A017) was verified to have an intra/inter-precision of less than 10%.
The sensitivity of ClinMax™ Human IFN-γ ELISA Kit, PRO (Cat. No. CEA-C006) is 3.25 pg/mL.
ClinMax™ Human IFN-γ ELISA Kit, PRO (Cat. No. CEA-C006) was verified to have an intra/inter-precision of less than 10%.
Diseases that are commonly present during sample collection such as jaundice (elevated bilirubin), hemolysis (elevated hemoglobin), and lipemia (elevated triglyceride) were simulated. Bilirubin, hemoglobin, and triglycerides were individually spiked into the sample matrix at a concentration of 20 mg/dL, 3500 g/dL, 2.0 g/L, respectively to evaluate matrix effect on our kits.
Anticoagulant effect was tested by spiking the sample with either heparin, EDTA, or sodium citrate at a concentration of 40U/mL, 4mg/mL, and 40mg/mL, respectively.