Human Th1/Th2 Cytokine Kit-2 (Flow Cytometry Multiplex Bead Assay)

用户评价
货号-规格
价格
Qty.
FCMh-002-50tests
¥7000.00
FCMh-002-100tests
¥12600.00
合计0件 产品金额¥ 0

产品详情

  • 产品参数(Product Specifications)

    Assay Type
    FACS
    Analyte
    IL-2, IL-4, IL-5, IL-10, TNF-α, IFN-γ
    Format
    50T
    Reactivity
    Human
    Regulatory Status
    RUO
    Sensitivity
    IL-2 (0.25 pg/mL), IL-4 (0.32 pg/mL), IL-5 (1.15 pg/mL), IL-10 (0.1 pg/mL), TNF-α (0.78 pg/mL), IFN-γ (0.29 pg/mL)
    Standard Curve Range
    9.8-10000 pg/mL (TNF-α, IFN-γ), 9.8-5000 pg/mL (IL-2, IL-4, IL-5, IL-10)
    Assay Time
    3 hr
    Suitable Sample Type
    Human serum, Human plasma, Cell culture supernatants
    Sample volume
    30 μL

  • 产品概述(Product Overview)

    T helper cells (Th) play a vital role in the adaptive immune system by suppressing or regulating immune responses. After Th actived, it will differentiate into T-helper 1 (Th1) or T-helper 2 (Th2) effector cells. These two subsets are characterized by their distinct cytokine expression pattern and the immune function they mediate. Th1 and Th2 cells each produce a specialized combination of cytokines that depends on type of pathogen that the helper T cell has recognized-some cytokines are more effective than others in the process of eliminating certain invaders. In general, TH1 cytokines play the role of immune killing, while Th2 cytokines play the role of immune protection. Th1/Th2 paradigm provides rationale for developing new vaccines against infectious diseases and novel strategies for the therapy of allergic and autoimmune disorders.

  • 应用说明(Application)

    The Human Th1/Th2 Cytokine Kit can be used to quantitatively measure Interleukin-2 (IL-2), Interleukin-4 (IL-4), Interleukin-5 (IL-5), Interleukin-10 (IL-10), Tumor Necrosis Factor-α (TNF-α), and Interferon-γ (IFN-γ) protein levels in a single sample.The kit performance has been optimized for analysis of specific cytokines in tissue culture supernatants, EDTA plasma, and serum samples.

    It is for research use only.

  • 存储(Storage)

    The unopened kit is stable for 12 months from the date of manufacture if stored at 2°C to 8°C.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • 组分(Materials Provided)

    Catalog
    Product Name
    Size
    FMBc007-02
    Anti-human IL-2 Antibody-coupled APC-beads-D01
    50 tests
    IL2-PFS426
    PE-Labeled Monoclonal Anti-human IL-2 Antibody, Rabbit IgG
    50 tests
    FMBc008-02
    Anti-human IL-4 Antibody-coupled APC-beads-D05
    50 tests
    IL4-PFS269
    PE-Labeled Monoclonal Anti-human IL-4 Antibody, IgG1
    50 tests
    FMBc014-02
    Anti-human IL-5 Antibody-coupled APC-beads-C03
    50 tests
    FABm030-01
    PE labeled Monoclonal Anti-Human IL-5 Antibody, Rat IgG1
    50 tests
    FMBc017-02
    Anti-human IL-10 Antibody-coupled APC-beads-D08
    50 tests
    IL0-PFS428
    PE labeled Monoclonal Anti-Human IL-10 Antibody, Rat IgG1
    50 tests
    FMBc010-02
    Anti-human TNF-α Antibody-coupled APC-beads-D13
    50 tests
    TNA-PFM494
    PE-Labeled Monoclonal Anti-TNF-alpha Antibody, human IgG1 (16H5)
    50 tests
    FMBc011-02
    Anti-human IFN-γ Antibody-coupled APC-beads-D17
    50 tests
    IFN-PFM412
    PE-Labeled Monoclonal Anti-IFN-gamma Antibody, human IgG1 (8C5F8)
    50 tests
    FMBf001-02
    APC Positive Control-01
    0.5 mL
    FMBf001-01
    PE Positive Control-01
    0.5 mL
    FCMP-02
    96-well Sealing film
    1 plate
    FCMP-01
    96-Well V-Bottom Assay Plate
    2 pieces
    FCMB-03
    1* Assay Buffer
    50 mL
    FCMB-04
    1*Wash Buffer
    50 mL
    IL2-H51P3
    Calibrator (IL-2, IL-4, IL-6, IL-10, TNF-α, IFN-γ)
    5 μg for each
    IL5-H52H3
    Calibrator (IL-5)
    50 μg

  • 原理(Assay Principles)

    The Human Th1/Th2 Cytokine Kit-2 is a multiplex bead-based indirect immunofluo-rescence assay, utilizing flow cytometry for data acquisition and classification. The beads conjugated with specific antibody, target protein (IL-2/4/5/10, TNF-α, IFN-γ) in specimens and PE-conjugated detection antibody form a sandwiches complex as bead-analyte-detection antibody. The intensity of PE fluorescence signal in proportion to the target protein in specimens, are assessed by flow cytometry. The present assay has been optimized for quantitatively analysis for the IL-2/4/5/10, TNF-α, IFN-γ in cell culture supernatant, plasma, and serum samples.

  • 质量管理控制体系(QMS)

    1. 质量管理体系(ISO, GMP)
    2. 质量优势
    3. 质控流程

推荐产品

数据展示

  • 典型数据-Typical Data

    Please refer to DS document for the assay protocol.

     Th1/Th2 cytokine TYPICAL DATA

    A double logarithmic fitting curve was plotted for each cytokine( IL-2, IL-4, IL-5, IL-10, TNF-α, IFN-γ). The present curve of IL-2/IL-4/IL-5/IL-10 was ranging from 9.8 pg/ml to 5000 pg/mL, TNF-α/IFN-γ raging from 9.8 pg/mL to 10000 pg/mL .

  • 活性(Bioactivity)-FCM

    Please refer to DS document for the assay protocol.

     Th1/Th2 cytokine FCM

    A representative scatter plot showing single bead population in P1 gate (left), the beads conjugated with analyte-sepcific antibody differntiated by APC fluorescence intensity (middle), and fluorescence signal in propotion to concentration of the analyte was measured for each cytokine in PE channel (right). Data was generated on Beckman Cytoflex S Flow Cytometer, equipped with blue laser (561 nm) and red laser (640 nm).

用户评价
发表评论

前沿进展

 
联系我们
项目合作
查看更多项目
实验案例分析
查看更多案例分析
  • 产品基础信息
  • 产品详情
  • 推荐产品
  • 数据展示
  • 用户评价