产品详情
产品概述(Product Overview)
Human Complement C3 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant Human Complement C3 that is present in biological samples, such as serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Ready-to-use reagents to save assay time.
产品参数(Product Specifications)
Assay TypeSandwich-ELISAAnalyteComplement C3Format96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity0.2 ng/mLAssay Time2.75 hrSample volume50 μLRange0.39 ng/mL-25 ng/mLSample TypeFor the quantitative determination of human Complement C3 in serum, plasma and cell supernatant.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
应用说明(Application)
The kit is developed for quantitative detection of natural and recombinant human Complement C3 in serum, plasma and cell culture supernatants.
It is for research use only.
流程图(Workflow)

存储(Storage)
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
组分(Materials Provided)
IDComponentsSizeCEA263-C01Pre-coated Anti-Complement C3 Antibody Microplate1 plateCEA263-C02Human Complement C3 Standard1 μg×2CEA263-C03Biotin-Anti-Complement C3 Antibody1.25 μgCEA263-C04Biotin-Antibody Dilution Buffer8 mLCEA263-C05Streptavidin-HRP Con. Solution500 μLCEA263-C06Streptavidin-HRP Dilution Buffer15 mLCEA263-C0720× Washing Buffer50 mLCEA263-C08Sample Dilution Buffer15 mL×2CEA263-C09Substrate Solution12 mLCEA263-C10Stop Solution6 mL质量管理控制体系(QMS)
推荐产品
数据展示
典型数据-Typical Data
Please refer to DS document for the assay protocol.

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was cal-culated based on the results of the standard curve. The minimum detectable con-centration of Complement C3 is less than 0.2 ng/mL.
样本值(Sample Values)
Twenty four healthy donor serum samples were evaluated for the concentrations of human Complement C3 in assay.

批内差异(Intra-Assay Statistics)
Ten replicates of each of three samples containing different Complement C3 concentrations were tested in one assay. Acceptable criteria: CV<10%.

批间差异(Inter-Assay Statistics)
Three samples containing different concentrations of Complement C3 were tested in independent assays. Acceptable criteria: CV<15%.

回收率(Recovery)
Recombinant Complement C3 was spiked into three diluted human serum samples, and then analyzed. The average recovery of Complement C3 for serum samples is 98.9%.