登录 | 注册    关注公众号  
微信公众号
搜索
 >  Beads>AHG >MPC-A004

Anti-Human IgG-coupled Magnetic Beads (recommended for MPCLIA)

The Magnetic Stand (Cat.No. MB-01 & Cat.No. MB-02) can be used in conjunction with Beads. 

ItemsDetails
Detection MethodChemiluminescence
Product TypeMagnetic Beads (Anti-Human IgG)
Quantity Size10mg / 100mg
Physical Appearancelyophilized powder mixture
Particle size2.8µm
Beads SurfaceHydrophilic
Amount of Coupled ProteinAbout 133 pmol (20 μg) Anti-Human IgG / mg Beads
Binding Capacity2-5ug human antibody or Human IgG Fc tag proteins / mg beads
Emission WavelengthMeasured relative light units (RLU) at 430 nm

背景(Background)

The Anti-Human IgG-coupled Magnetic Beads are 2.8 µm superparamagnetic particles covalently coupled to a highly affinity Monoclonal mouse anti-human IgG antibody. The beads can be used to capture the human IgG in Chemiluminescence procedures. The antibody reacts with the Fc portion of human IgG heavy chain but not with the Fab portion of human IgG. No antibody was detected against human IgM or IgA, or against non-immunoglobulin serum proteins. The antibody has been tested by ELISA and/or solid-phase adsorbed to ensure minimal cross-reaction with mouse, cynomolgus and bovine serum proteins, but it is not sure if the product cross-react with immunoglobulins from other species. The Anti-Human IgG-coupled Magnetic Beads is easy to capture the human IgG, and the bounded antibody have no activity lost, this ready to use products could greatly save your protein coupling time and hassle, and help us get the best performance and highly reproducible results.

应用说明(Application)

The Anti-Human IgG-coupled Magnetic Beads is used to capture the human IgG, it can combination with Acridinium ester markers in chemiluminescence technology, The Acridinium ester markers such as Streptavidin-Acridinium ester can capture the biotinylated proteins or molecules, this allows detection of antigen and antibody binding or antibody screening.

*The Isotype control (Cat. No. SMB-B01) is sold separately.

重构方法(Reconstitution)

See Certificate of Analysis (CoA) for detailed instruction.

存储(Storage)

Upon receipt, please store the Beads at -20°C. The shelf life is 1 year at -20 °C.

Please avoid more than 3 freeze-thaw cycles once reconstitution, immediate use after reconstitution is highly recommended.

制剂(Formulation)

Please contact us for detailed information.

Contact us for customized product form or formulation.

 

活性(Bioactivity)-MPCLIA

AHG MPCLIA

Immobilized 0.04 μg /Test of Biotinylated SARS-CoV-2 Spike RBD, His,Avitag (Cat. No. SPD-C82E9) to the Streptavidin-Acridine ester (Cat. No. STN-NA114, 0.008 μg /Test), incubated with 100 μL /Test of Anti-SARS-CoV-2 Spike RBD Antibody, Chimeric mAb, Human IgG1 (AM122) (Cat. No. S1N-M12A1) at increasing concentration coupled to Anti-Human IgG-coupled Magnetic Beads (used for MPCLIA) (Cat. No. MPC-A004) (10 μg beads/Test). Detection was performed with sensitivity of 0.39 ng/mL in Magnetism particulate chemiluminescence immunoassay (MPCLIA) (KEYSMILE, SMART 6500S) (QC tested).

Protocol

AHG MPCLIA

The MPCLIA assay shows that Anti-Human IgG-coupled Magnetic Beads (used for MPCLIA) (Cat. No. MPC-A004) is stable at 37°C for 10 days.

AHG MPCLIA

The MPCLIA assay shows that Anti-Human IgG-coupled Magnetic Beads (used for MPCLIA) (Cat. No. MPC-A004) is stable after freezing and thawing 3 times.

 

前沿进展

 
 
货号/价格
文档
联系电话:
+86 400-682-2521(全国)
010-53681107(北京)
021-50850665(上海)
运输方式
订单邮箱:
order.cn@acrobiosystems.com
技术支持邮箱:
tech.cn@acrobiosystems.com
前沿进展
点击查看详细
相关产品
View All AHG

消息提示

请输入您的联系方式,再点击提交!

确定